1.2.1 Using practical apparatus and techniques correctly

OCR Specification focus:
‘Use a wide range of practical apparatus and techniques correctly and safely, as required across the specification and practical endorsement activities.’

Practical competence in physics demands not only theoretical understanding but also skillful and safe handling of laboratory apparatus. Mastery of apparatus use ensures valid, reliable, and reproducible results in all investigations.

Understanding the Role of Practical Techniques

Using apparatus correctly underpins the accuracy and reliability of experimental outcomes. In the OCR A-Level Physics course, students are expected to demonstrate a confident command of a wide range of techniques encountered across all modules, from mechanics and electricity to quantum and medical physics.

Importance of Technique in Physics

The correct use of apparatus allows:

  • Precise measurements of physical quantities.

  • Control of variables to isolate effects.

  • Reduction of systematic and random errors.

  • Safe operation within recognised laboratory standards.

Competent technique is not merely mechanical; it involves understanding the principles behind each instrument and adapting methods to experimental requirements.

Categories of Practical Apparatus and Techniques

Mechanical Measurement

Students must handle mechanical measuring instruments accurately to obtain trustworthy data.

  • Meters and Rules – for measuring lengths to the nearest millimetre. Avoid parallax by keeping the eye perpendicular to the scale.

  • Micrometers and Vernier Callipers – for sub-millimetre precision in diameter or thickness measurements. Regular calibration against a standard gauge ensures accuracy.

A labelled Vernier calliper showing outside and inside jaws, depth probe, main scales, and Vernier scales. The diagram illustrates where readings are taken and how the Vernier improves resolution. This vector image is clean and ideal for discussing calibration and zero checks. Source

  • Stopwatches and Light Gates – used to record time intervals with high resolution in motion experiments. Consistent reaction timing and repeated trials minimise uncertainty.

Calibration: The process of adjusting or verifying the accuracy of an instrument by comparing it with a known standard.

Between trials, ensure apparatus is returned to its zero setting and used in stable environmental conditions (e.g. level surfaces, constant temperature).

Electrical and Electronic Apparatus

Electrical investigations require the correct connection and use of circuit components to measure voltage, current, and resistance safely.

  • Power Supplies – ensure voltage and polarity are appropriate for circuit elements.

  • Multimeters – used as ammeters (in series) or voltmeters (in parallel). Select the correct range to prevent damage.

Schematic diagrams showing the voltmeter (V) connected in parallel across components and the ammeter (A) connected in series with the circuit. These figures emphasise the standard connection rules needed for valid measurements. Extra detail present: the figure also references internal resistance rrr of the source, which you may ignore if first introducing connection conventions. Source

  • Resistors, Lamps, and Thermistors – must be identified and connected according to circuit diagrams.

  • Oscilloscopes – display waveforms for alternating currents; time-base and sensitivity controls should be adjusted to centre and scale the signal appropriately.

A labelled oscilloscope diagram indicating key controls and the display graticule. Use it to explain how vertical sensitivity and time-base are adjusted before measuring amplitude and period. Extra detail present: the panel shows additional control groupings; focus students on time/div and volts/div for this sub-subtopic. Source

EQUATION
—-----------------------------------------------------------------
Ohm’s Law (V, I, R) = V = I × R
V = Potential difference across a component (volts, V)
I = Current through the component (amperes, A)
R = Resistance of the component (ohms, Ω)
—-----------------------------------------------------------------

When connecting circuits, double-check wiring before energising. Use low voltages where possible and ensure hands are dry to prevent electric shock hazards.

Thermal and Environmental Apparatus

Experiments in thermodynamics or materials require accurate temperature and heat transfer measurement.

  • Thermometers and Digital Probes – should be immersed appropriately without touching container sides.

  • Heating Elements and Water Baths – ensure uniform heating and avoid overheating liquids.

  • Insulating Materials – reduce heat loss for more accurate results.

For gases and pressure experiments, use pressure sensors or manometers, confirming they are correctly zeroed before readings. Always wear protective gloves and goggles when handling heated or pressurised systems.

Optical and Wave Apparatus

Optical measurements depend on correct alignment and positioning.

  • Rays and Lenses – light sources must be collimated; lenses cleaned and centred.

  • Diffraction Gratings and Slits – spacing and angles must be precisely measured for wavelength determination.

  • Microscopes and Telescopes – adjust focus carefully; use fine adjustment for sharp images.

Collimated Light: A beam in which rays are parallel, producing minimal divergence and higher accuracy in optical measurements.

Optical benches must be level, and distances between components measured along the central axis to avoid parallax or angular displacement errors.

Safe Laboratory Practice

General Safety Principles

Safety underpins all practical work. The OCR specification expects adherence to health and safety regulations throughout all activities.

Key safety principles include:

  • Wearing eye protection when dealing with projectiles, heat, or chemicals.

  • Keeping electrical apparatus dry and switching off when not in use.

  • Clamping tall or heavy apparatus to prevent toppling.

  • Reporting and isolating damaged equipment immediately.

Specific Risk Management

  • Electrical Experiments: Avoid exposed wires and overloading circuits.

  • Thermal Experiments: Use heatproof mats and handle apparatus with tongs.

  • Optical Work: Never look directly into intense light sources or lasers.

  • Mechanical Experiments: Secure moving parts and ensure apparatus is stable on benches.

Risk Assessment: A structured evaluation of potential hazards in an experiment, including the likelihood and severity of harm, used to implement suitable control measures.

Ensuring Correct Technique and Accuracy

Repetition and Consistency

Repeat measurements several times and calculate a mean value to reduce random error. Consistency in measurement method—using the same equipment and alignment—enhances reliability.

Zero Error and Instrument Calibration

Before taking readings:

  • Check for zero errors and correct them mathematically if present.

  • Regularly calibrate digital instruments.

  • Confirm the sensitivity and range are appropriate for expected values.

Minimising Human Error

Adopt consistent reading practices:

  • Take readings at eye level to avoid parallax.

  • Record data immediately in a clearly structured table with correct units and headings.

  • Maintain constant environmental conditions, especially in temperature or light-sensitive experiments.

Integration Across Practical Endorsements

Using apparatus correctly links to all aspects of the Practical Endorsement in OCR Physics, including:

  • Planning: Selecting appropriate apparatus and predicting achievable precision.

  • Implementation: Operating the chosen apparatus accurately and safely.

  • Analysis: Understanding limitations of each instrument’s sensitivity and uncertainty.

  • Evaluation: Suggesting improvements based on the apparatus’ performance and data consistency.

Through consistent practice and critical reflection, students demonstrate both technical competence and scientific integrity, essential for success in advanced experimental physics.

FAQ

Accuracy refers to how close a measurement is to the true value, while precision describes how consistent repeated measurements are.

For example, a voltmeter reading close to the actual voltage is accurate; repeating that reading with little variation indicates precision.

High precision does not guarantee accuracy — a miscalibrated instrument can produce consistent but incorrect values.

Zero error occurs when a measuring instrument does not read zero when the measured quantity is zero.

It introduces a systematic error that shifts all results by the same amount. To correct for this:

  • Measure the zero reading before starting.

  • Subtract or add this offset from all readings.

Instruments such as micrometers, ammeters, and thermometers commonly require this check.

Digital instruments minimise parallax and reading interpretation errors by providing clear numerical outputs.

However, they must still be used correctly:

  • Ensure the range and resolution are suitable for expected values.

  • Calibrate regularly, as electronic drift can affect readings.

  • Record the number of decimal places shown to reflect true precision.

Although more reliable, digital devices can mask uncertainty if the user fails to consider instrument limits.

Data loggers automatically record measurements over time, improving both accuracy and consistency.

Advantages include:

  • Elimination of human reaction time errors.

  • Continuous data collection, useful for monitoring changes in temperature, voltage, or current.

  • Easy export of large datasets for analysis.

They are particularly beneficial in long-duration or repetitive experiments where maintaining consistent timing is difficult manually.

Temperature, humidity, and air pressure can subtly alter measurements and apparatus behaviour.

For example:

  • Metal rulers expand with temperature, altering length measurements.

  • Electronic instruments may drift if exposed to heat or moisture.

  • Air movement can disturb sensitive balance readings.

To reduce environmental effects:

  • Conduct experiments in stable conditions.

  • Allow apparatus to reach room temperature before use.

  • Record environmental variables if they may influence results.

Practice Questions

Question 1 (2 marks)
A student uses a micrometer screw gauge to measure the diameter of a thin wire.
(a) State one precaution the student should take to ensure an accurate measurement.
(b) Explain why this precaution is necessary.

Mark scheme

  • (a) Any one from:

    • Ensure the micrometer is zeroed before use. (1)

    • Use the ratchet mechanism to apply consistent pressure. (1)

    • Take multiple readings and calculate a mean. (1)

  • (b) Any one appropriate explanation:

    • Zeroing removes systematic error caused by instrument offset. (1)

    • Using the ratchet ensures a consistent contact force, avoiding deformation of the wire. (1)

    • Averaging reduces the effect of random error. (1)

(Max 2 marks total)

Question 2 (5 marks)
A student is investigating the potential difference across a resistor using a voltmeter and an ammeter.
(a) Describe how the student should connect the circuit to measure both current and potential difference correctly. (2)
(b) Explain how incorrect connections could affect the results. (2)
(c) State one safety precaution the student should follow when setting up and using the circuit. (1)


Mark scheme
(a)

  • Ammeter connected in series with the resistor. (1)

  • Voltmeter connected in parallel across the resistor. (1)

(b)

  • If the ammeter were connected in parallel, it would have very low resistance and could cause a short circuit or damage. (1)

  • If the voltmeter were connected in series, its high resistance would greatly reduce current flow, giving false readings. (1)

(c)

  • Use low voltages to avoid overheating or damaging components. (1) OR

  • Check circuit connections are correct and power supply is switched off before altering wiring. (1)

(Max 5 marks total)